Description of the individual safety relays
3.8 3TK28 safety relays with contactor relay enabling circuits
3TK28 safety relays
Manual, 07/2016, NEB926157502000/RS-AB/003
163
IEC 60947-5-1, IEC 60000-4-3,
IEC 60000-4-5, IEC 60000-4-6
• according to DIN 40719 extendable after IEC 204-2
according to IEC 750
KT
• according to DIN EN 61346-2
F
Number of sensor inputs 1-channel or 2-channel
cascading and in-service switching
Type of the safety-related wiring of the inputs
single-channel and two-channel
transverse contact-secure
Yes
Safety Integrity Level (SIL) according to IEC 61508
SIL claim limit (for a subsystem) according to EN 62061
Safety integrity level (SIL)
for delayed release circuit
—
• according to ISO 13849-1
e
• for delayed release circuit according to ISO 13849-1
—
• according to EN 954-1
4
• according to ISO 13849-1
4
Safety device type according to IEC 61508-2
Probability of dangerous failure per hour (PFHD)
with high
demand rate according to EN 62061
1/h 0.000000011
for proof test interval or service life
a 20