EasyManua.ls Logo

Siemens 3TK28 - Technical Data 3 TK2821; 3 TK2824

Siemens 3TK28
206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the individual safety relays
3.6 3TK28 safety relays with relay enabling circuits
3TK28 safety relays
58 Manual, 07/2016, NEB926157502000/RS-AB/003
3.6.4.7
Technical data 3TK2821 / 3TK2824
3TK2821-.C...
3TK2824-.B...
3TK2824-.C...
EMC emitted interference
EN 60947-5-1
Item designation
according to DIN 40719 extendable after
IEC 204-2 according to IEC 750
KT
according to DIN EN 61346-2
F
Number of sensor inputs 1-channel or 2-channel
1
Design of the cascading
none
Type of the safety-related wiring of the inputs
single-channel or single-channel and two-channel
Product feature transverse contact-secure
No
Safety Integrity Level (SIL) according to IEC 61508
SIL3
SIL claim limit (for a subsystem)
according to
EN 62061
1
Safety integrity level (SIL)
for delayed release
circuit according to IEC 61508
Performance Level (PL)
according to ISO 13849-1
e
for delayed release circuit according to ISO
13849-1
Category
according to EN 954-1
3
according to ISO 13849-1
3 2
Safety device type according to IEC 61508-2
Type A
Probability of dangerous failure per hour (PFHD)
with high demand rate according to EN 62061
1/h
0.0000000011 0.00000000087
T1 value
for proof test interval or service life
according to IEC 61508
a
20
Number of outputs
as contact-affected switching
element as NO contact safety-related
as NC contact for reporting function
instantaneous switching
1 0
as NO contact safety-related instantaneous
switching
3 2
as NO contact safety-related delayed switching
0
Stop category according to DIN EN 60204-1
0
Design of the input
cascading-input/functional switching
No
feedback input
Yes
start input
Yes

Table of Contents