Descriptions of functions
10.6 Communication via SINAMICS Link
SINAMICS DCM DC Converter
524 Operating Instructions, 12/2018, A5E34763375A
10.6.7
Function diagrams and parameters
Function diagrams (see the SINAMICS DCM List Manual)
2197
Control Unit communication
SINAMICS Link overview
(r0108.31 = 1, p8835
= 3)
2198
Control Unit communication
SINAMICS Link configuration
(r0108.31 = 1, p8835 = 3)
2199
Control Unit communication
SINAMICS Link receive data
(r0108.31 = 1, p8835 = 3)
2200
Control Unit communication
SINAMICS Link send data
(r0108.31 = 1, p8835 = 3)
Overview of important parameters (see SINAMICS DCM List Manual)
p0115[0]
Sampling time for additional functions
p2037
IF1 PROFIdrive STW1.10 = 0 mode
r2050[0...31]
CO: IF1 PROFIdrive PZD receive word
p2051[0...31]
CI: IF1 PROFIdrive PZD send word
r2060[0...30]
CO: IF1 PROFIdrive PZD receive double word
p2061[0...30]
CI: IF1 PROFIdrive PZD send double word
p8811
SINAMICS Link project selection
p8812[0...1]
SINAMICS Link cycle settings
p8835
CBE20 firmware selection
p8836
SINAMICS Link node address
p8839[0...1]
PZD interface hardware assignment
p8870[0...31]
SINAMICS Link PZD receive word
p8871[0...31]
SINAMICS Link PZD send word
p8872[0...31]
SINAMICS Link PZD receive address

Table of Contents