Descriptions of functions
10.8 Communication via Modbus TCP
SINAMICS DCM DC Converter
550 Operating Instructions, 12/2018, A5E34763375A
10.8.7
Messages and parameters
Faults and alarms (see DCM List Manual)
F01910
Fieldbus: Setpoint timeout
A01925
Modbus TCP connection interrupted
F08501
PN/COMM BOARD: Setpoint timeout
A08526
PN/COMM BOARD: No cyclic connection
A08555
Modbus TCP commissioning fault
Overview of important parameters (see SINAMICS DCM List Manual)
p0978[0...n]
List of drive objects
p2030
Fieldbus interface protocol selection
p2040
Fieldbus interface monitoring time:
r2050[0...19]
CO: IF1 PROFIdrive PZD receive word
p2051[0...24]
CI: IF1 PROFIdrive PZD send word
r2053[0...24]
IF1 PROFIdrive diagnostics PZD send word
r2054
PROFIBUS status
p8835
CBE20 firmware selection
p8839[0...1]
PZD interface hardware assignment
p8840
COMM BOARD monitoring time
r8850[0...19]
CO: IF2 PZD receive word
p8851[0...24]
CI: IF2 PZD send word
r8853[0...24]
IF2 diagnostics PZD send
r8854
COMM BOARD state
p8920[0...239]
PN Name of Station
p8921[0...3]
PN IP address
p8922[0...3]
PN default gateway
p8923[0...3]
PN Subnet Mask
p8924
PN DHCP mode
p8925
PN interfaces configuration
p8940[0...239]
CBE2x Name of Station
p8941[0...3]
CBE2x IP address
p8942[0...3]
CBE2x Default Gateway
p8943[0...3]
CBE2x Subnet Mask
p8944
CBE2x DHCP mode
p8945
CBE2x interfaces configuration