Descriptions of functions
10.34 Diagnostics
SINAMICS DCM DC Converter
632 Operating Instructions, 12/2018, A5E34763375A
Note
Errors and alarms are stamped with this system runtime.
If a connected AOP30 is paramete
rized as the time-of-day master (see Chapter "Assigning
parameters to make AOP30 time
-of-day master (Page 402)"
), faults and alarms are provided
with a
real-time stamp.
Relative system runtime
The relative system runtime since the last POWER ON is displayed in p0969 (Control Unit)
in ms. The counter runs over after 49 days.
10.34
Diagnostics
10.34.1
Diagnostic memory
To provide support for troubleshooting and remedying problems, the SINAMICS DC
MASTER records various types of data in a diagnostics file. Siemens specialists can use the
contents of this file to glean more in-depth information about the cause of inexplicable faults
or other problems such as blown fuses or defective thyristors.
When contacting Siemens with queries related to problems of this type, it is, therefore,
advisable that you both read out this file and e-mail a copy of it to the Siemens experts.
With parallel or series connection, the diagnostics files of
all
devices must always be read
out and sent to the Siemens experts.
Proceed as follows to read out the diagnostics file:
1. Insert the memory card in the drive.
2. Set p50832 = 1:
this copies the diagnostics file to the CompactFlash Card. A process which takes
approximately 2 minutes. Copying is complete when p50832 takes on the value 0 again.
3. The diagnostics file is called
DiagStor.spd
, is approx. 600 KB in size, and can be found in
the
\USER\SINAMICS\DATA\LOG
directory on the memory card.
For more details on the diagnostic memory, please refer to function diagram FP8052.