PROGRAMMING | 115
the tool at tool enable set screen.
Brake Reaction: When tool detects a certain value of off-range, occur alarm screen.
(User select, Retract and stop)
Stop : If tool broken, display tool broken status screen. And machine stop
Default value, If press this soft key, set default value
Recommend value, All factor change to automatic mode
, Assign G-code : User define G-code for not detect current .(TLM Tool setting detail 3,
OEM section)
Delete All Data : Delete all TLM data(about 1min)
(8) Tool Broken Screen
If TLM detects a certain value of off-range, it will generate Cycle alarm.
If TLM detects a certain value of off-range, it will generate Cycle alarm screen
automatically. And then If press RESET (on MCP button), the alarm screen disappears.
Tool Broken position(W.C.S)
Reaction : If this screen display, user can be selected to next situation. (Change to
Sister Tool, Stop, Continue)
Continue continue cutting
Retract + Stop machine stop
Continue with ST tool change to replacement tool
Violation Value : Broken axis, detected current[A]