EasyManua.ls Logo

Siemens SCALANCE X-300

Siemens SCALANCE X-300
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
8.1 X-300 technical specifications
SCALANCE X-300
148 Operating Instructions, 10/2010, A5E01113043-10
Connection of end devices or network components: Plug-in terminal block
Connector for:
Device:
SCALANCE
over twisted pair over FO cable Power supply Signaling contact
X320-1 FE 20 x RJ-45 jacks with MDI-X
assignment 10/100 Mbps (half
/ full duplex)
1 x SC duplex socket (MM)
(100 Mbps, full duplex to
100BaseFX)
1 x 4-pin 1 x 2-pin
X320-3LD FE 20 x RJ-45 jacks with MDI-X
assignment 10/100 Mbps (half
/ full duplex)
1 x SC duplex socket (MM)
2 x SC duplex sockets (SM)
(100 Mbps, full duplex to
100BaseFX)
1 x 4-pin 1 x 2-pin
X306-1LD FE 6 x RJ-45 jacks with MDI-X
assignment 10/100 Mbps
(half / full duplex)
1 x SC duplex socket (SM)
(100 Mbps, full duplex to
100BaseFX)
1 x 4-pin 1 x 2-pin
X307-3 7 x RJ-45 jacks with MDI-X
assignment 10/100 Mbps (half
/ full duplex)
3 x SC duplex sockets
(1000 Mbps, full duplex to
1000BaseSX)
1 x 4-pin 1 x 2-pin
X307-3LD 7 x RJ-45 jacks with MDI-X
assignment 10/100 Mbps (half
/ full duplex)
3 x SC duplex sockets
(1000 Mbps, full duplex to
1000BaseLX)
1 x 4-pin 1 x 2-pin
X308-2 7 x RJ-45 jacks with MDI-X
assignment 10/100 Mbps (half
/ full duplex)
1 x RJ-45 socket with MDI-X
pinning 10/100/1000 Mbps
(half/ full duplex)
2 x SC duplex sockets
(1000 Mbps, full duplex to
1000BaseSX)
1 x 4-pin 1 x 2-pin
Table 8- 5 Electrical data part 1
Type Power supply voltage
24 VDC
(18-32 VDC)
Safety extra-low voltage (SELV)
Power loss at 24 VDC
X304-2FE 6.2 W
X306-1LD FE 4.8 W
X307-3 9.6 W
X307-3LD 9.6 W
X308-2 9.6 W
X308-2LD 9.6 W
X308-2LH 9.6 W
X308-2LH+ 9.6 W
X310 9.6 W
X310FE 9.6 W
X320-1 FE 9.6 W
X320-3LD FE 12 W

Table of Contents