Approvals, certificates, standards
9.3 Product group XR-300M
SCALANCE X-300
218 Operating Instructions, 10/2010, A5E01113043-10
Table 9- 3 Overview of the approvals
c-UL-us c-UL-us
for hazardous
locations (*)
FM
1
C-TICK CE ATEX95
Zone 2 (*)
E1 Device:
SCALANCE
(Variant)
UL
60950
1
CSA
C22.2
No.
60950
1
UL1604 and
UL2279-15
CSA C22.2
No. 213-M1987
CL. 1, Div. 2
GP.A.B.C.D T..
CL. 1, Zone 2,
GP. IIC, T..
FM 3611
CL.1, Div.2
GP. A.B.C.D
T..
CL.1, Zone
2, GP. IIC,
T..
Ta:..
AS/NZS
2064
(Class A).
EN
61000-6-4
Class A,
EN
61000-6-2
EN 60079-
15:2005 ,
EN 60079-
0:2006
II 3 G Ex nA
II T..
KEMA 07
ATEX
0145X
-
XR324-12M 2 x 24 V DC, cable
outlet front
-
XR324-12M 1 x 100 to 240 V AC,
cable outlet front
*) - - - -
XR324-12M 2 x 24 V DC, cable
outlet rear
-
XR324-12M 1 x 100 to 240 V AC,
cable outlet rear
*) - - - -
*) Note: UL 508 CSA C22.2 No. 142-M1987
(*) For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to
the type plate.
9.3.6 XR-300M mechanical stability (in operation)
IEC 60068-2-6 vibration IEC 60068-2-27 shock IEC 60068-2-6 vibration *) Device:
SCALANCE
(Variant)
10 – 58 Hz: 0.15mm
58 – 500 Hz: 1 g
1 octave/min,
10 cycles
15 g, 11 ms duration
6 shocks per axis
5 – 8.51 Hz: 7 mm
8.51 – 500 Hz: 1 g
1 octave/min,
10 cycles
XR324-12M (2 x 24 V DC, cable outlet front)
XR324-12M (1 x 100...240 V AC, cable outlet front)
XR324-12M (2 x 24 V DC, cable outlet rear)
XR324-12M (1 x 100...240 V AC, cable outlet rear)
*) Note: When rack mounted with 4 securing points