10-87© Siemens AG 2007 All Rights Reserved
SICLOCK
®
TC 400
Parameter Table 10
Table 10-1 List of the parameters of SICLOCK TC 400
Access
1)
/ No.
Parameter Entry Value Range / Default
Time
0.09.04
Local Time time and date
0.09.02
UTC Time time and date
0.09.06
Time Zone offset from UTC to zone time Min:
Max:
Default:
UTC-12:00 h
UTC+14:00 h
UTC+01:00 h
Time/Advanced
0.09.07
Daylight Saving Time enable Min:
Max:
Default:
Yes
No
Yes
time when changing over from
standard time to daylight sav-
ing time
Min:
Max:
Default:
February, third Sunday, 00:00
apply a definite date and time
March, last Sunday, 02:00
time when changing back from
daylight saving time to stan-
dard time
Min:
Max:
Default:
February, third Sunday, 00:00
apply a definite date and time
October, last Sunday, 03:00
hours Min:
Max:
Default:
+1 h
+2 h
+1 h
0.09.08
Definite Daylight Saving
Time
definite time and date when
changing back from daylight
saving time to standard time
definite time and date when
changing over from standard
time to daylight saving time
0.09.05
Leap Seconds[20] time and date
size Min:
Max:
Default:
-1 s
+1 s
+0 s