6-6
Box PC 820 / PC FI45 V2, Manual
A5E00051531-03
Socket Connector X6
Connection to the inverter module.
Pin No. Connection to Signal Name Remarks
1 P12V P12V Power supply for inverter
2 X6-2 BL_ON Switch on signal for back light
3 X6-3 BL_CTRL_1 Brightness adjustment
4 X6-4 BL_CTRL_2 Brightness adjustment
5 X6-5 BL_CTRL_3 Brightness adjustment
6 GND GND
7 GND GND
8 P5V P5V
9 P5V P5V
10 P12V P12V
Socket Connector X7, X8
Voltage supply 5V/12V, not fitted.
Pin No. Connection to Signal Name Remarks
1 P12V P12V Derived from power supply to
inverter
2 GND GND
3 GND GND
4 P5V P5V
Socket Connector X9
Connection for reset key.
Pin No. Connection to Signal Name Remarks
1 X10-1, X4-17, X4-31 RESET- Reset signal (low active)
2 GND GND
Socket Connector X10
Connection for reset, not fitted.
Pin No. Connection to Signal Name Remarks
1 X9-1, X4-17, X4-31 RESET- Reset signal (low active)
2 GND GND
Front Adapter Module (FI45)