11-5
Box PC 820 / PC FI45 V2, Manual
A5E00051531-03
SIMATIC PC - PG 6xx Connection to PLC-S5 Port
If you want to connect your device to the PLC-S5 port of a PG 6xx programming
device, you will need an adapter. In this case, the PC must be switched to active.
Please read the notes on changing over the TTY/COM 1 port to active in Chapter
1.3.
330 ohms
330 ohms
19
18
21
22
10
6
8
19
9
8
21
10
12
10 24
25
12
23
20
6
2
3
4
17
24
25
2
3
4
17
1
3
20
Casing
Casing
Shield/casing
GND
K3
K2
K1
+U
–U
+U
–U
Adapter
6ES5 731-6AG00
(Rel. 2)
Connecting cable
6ES5 733-2xxx0
PG 6xx
25-pin cannon plug connector
with S5/V.24 passive port
Rixx
25-pin cannon plug connector
Port: COM1/TTY
active
Figure 11-6 SIMATIC PC - PG 6xx Connection to PLC-S5 Port
SIMATIC PC - PG 7xx Connection in V.24 Operation
With this connecting cable you can connect your device to any PG 7xx.
Casing Shield
Casing Casing
ShieldCasing 1
3
2
5
4
20
7
17
6
RxD
TxD
CTS
RTS
DTR
GHD
AKENI
DSR
2
3
4
5
6
7
20
TxD
RxD
RTS
CTS
DSR
GHD
DTR
2
3
4
5
6
7
20
1
3
2
5
4
20
7
17
6
25-pin 25-pinConnecting cable: 6ES5733-0BD20
Pay attention to the connecting polarities!
Figure 11-7 SIMATIC PC - PG 7xx Connection in V.24 Operation
Connecting Cables
Siemens Distributor