Technical specifications
11.1 Technical specifications of the ET 200SP F-TM ServoDrive
F-TM ServoDrive
Equipment Manual, 02/2020, A5E47579503-AA
99
Potential separation channels
• between the channels and backplane bus
Yes
Isolation tested with 707 V DC/1 min, type test (between backplane
bus and functional ground)
2 according to EN 61800-5-1
Degree and class of protection
Standards, approvals, certificates
Standard for EMC according to EN 61800-3 Yes, according to second environment Category
Standard for drive acc. to EN 61800-5-1
Standard for drive acc. to EN 61800-5-2
Highest safety class achievable in safety mode
• Performance level according to ISO 13849-
1
Category 3, performance level d, according to EN
ISO 13849-1:2015
• SIL according to DIN EN 61800-5-2
SIL 2 according to EN 61800-5-2:2017
Pollution degree during storage and transport
Ambient temperature during operation
• horizontal installation, min.
-30 °C; No condensation, splash water, icing, salt
spray or oil mist permitted.
• horizontal installation, max.
60 °C; No condensation, splash water, icing, salt
spray or oil mist permitted. Note the derating
• vertical installation, min.
-30 °C; No condensation, splash water, icing, salt
spray or oil mist permitted.
• vertical installation, max.
50 °C
Ambient temperature during stor-
age/transportation
• Storage, min.
-40 °C
• Storage, max.
70 °C
Altitude during operation relating to sea level
• Installation altitude above sea level, max.
3 000 m
Cable length for motor, shielded, max.