EasyManuals Logo

Siemens SIMATIC IPC377G User Manual

Siemens SIMATIC IPC377G
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Maintaining and repairing the device
7.4 Installing and removing hardware
SIMATIC IPC377G
54 Operating Instructions, 07/2022, A5E51366314-AB
Procedure
Unscrew the marked five screws on the
bottom side of the box cover, and remove
the cover.
Slide the battery out 45 degrees from the
upper left, pull the battery out gently and
insert a new battery.
Note: The positive electrode (+) of the
battery should be positioned toward
the
outside of the device.
7.4.2 Replacing the memory module
Single channel memory
The motherboard provides one DDR4 memory sockets. The memory capacity of the device
can be upgraded to a maximum of 16 GB.
The table below shows the supported memory types of motherboard.
Module type
Module Size
Description
DDR4SDRAM
16GB
DDR4 up to 3200MT/S SODIMM 260pin
DDR4SDRAM
8GB
DDR4 up to 3200MT/S SODIMM 260pin
DDR4SDRAM
4GB
DDR4 up to 3200MT/S SODIMM 260pin
Requirements
The device is disconnected from the power supply.
All connecting cables on the device are unplugged.
The device is opened.
A T8 and a T10 screwdriver.
NOTICE
Electrostatic discharge
The electronic components on the PCBs are highly sensitive to electrostatic discharge.
Always take appropriate precautionary measures when handling these components. Refer
to the ESD directives on handling electrostatic sensitive components.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC377G and is the answer not in the manual?

Siemens SIMATIC IPC377G Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC377G
CategoryIndustrial PC
LanguageEnglish

Related product manuals