Configuring with Web Based Management
5.5 "System" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
107
"DNS Client" check box
Enable or disable the DNS client. You can configure other settings in "System > DNS
Client".
"SMTP Client" check box
Enable or disable the SMTP client. You can configure other settings in "System > SMTP
Client".
"Syslog Client"
check box
Enable or disable the Syslog client. You can configure other settings in "System > Syslog
Client".
"DCP Server"
drop-down list
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
Read/Write
With DCP, device parameters can be both read and modified.
Read-Only
With DCP, device parameters can be read but cannot be modified.
"Time"
drop-down list
Select the setting from the drop-down list. The following settings are possible:
Manual
The system time is set manually. You can configure other settings in "System > Time
> Manual Setting".
SIMATIC Time
The system time is set using a SIMATIC time transmitter. You can configure other
settings in "System > System Time > SIMATIC Time Client".
SNTP Client
The system time is set via an SNTP server. You can configure other settings in
"System > System Time > SNTP Client".
NTP Client
The system time is set via an NTP server. You can configure other settings in "System
> System Time > NTP Client".
"SNMP" drop-down list:
Select the protocol from the drop-down list. The following settings are possible:
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
SNMPv3
Access to device parameters is possible only with SNMP version 3. You can configure
other settings in "System > SNMP > General".
"SNMPv1/v2 Read-Only"
check box
Enable or disable write access to SNMP variables with SNMPv1/v2c.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W722-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W722-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W722-1
CategoryControl Unit
LanguageEnglish

Related product manuals