Configuring with Web Based Management
5.5 "System" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
132 Configuration Manual, 11/2014, C79000-G8976-C350-03
Procedure
1. Enable the "SMTP Client" option.
2. Enter the IP address of the SMTP server or the FQDN name in the "SMTP Server IP
Address" input box.
3. Click the "Create" button. A new entry is generated in the table.
4. In the "Receiver Email Address" input box, enter the e-mail address to which the device is
to send an e-mail if a fault occurs.
5. Click the "Set Values" button.
Note
Depending on the properties and configuration of the SMTP server, it may be necessary
to adapt the "Sender Email Address” box for the e
-mails. Check with the administrator of
the SMTP server.
See also
Address assignment with DHCP (Page 34)
5.5.10
DHCP
5.5.10.1
DHCP Client
Setting the DHCP mode
If the DHCP mode is activated, the DHCP client starts a DHCP request to a configured
DHCP server and is assigned an IPv4 address as the response. The server manages an
address range from which it assigns IPv4 addresses. It is also possible to configure the
server so that the client always receives the same IPv4 address in response to its request.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W722-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W722-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W722-1
CategoryControl Unit
LanguageEnglish

Related product manuals