Configuring with Web Based Management
5.10 "iFeatures" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
233
Procedure
1. Select the "Enable iPCF" option for the required WLAN interface.
You configure the security settings in "Security > WLAN > Basic".
5.10.2
iPCF-MC
Requirements to be able to use iPCF-MC:
Client SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 / 6GK5722-1FC00-
0AB0 (US version))
The management interface and data interface must be operated in the same frequency
band and mode and must match in terms of their wireless coverage. iPCF-MC will not
work if both wireless interfaces are equipped with directional antennas that cover different
areas.
The management interfaces of all access points to which a client can change must use
the same channel. A client scans only this one channel to find accessible access points.
Transmission based on IEEE801.11h (DFS) cannot be used for the management
interface. 801.11h (DFS) is possible for the data interface.
The client cannot be operated with "Use Allowed Channel only".
"Force roaming on Ethernet down" is automatically mirrored on the second interface.
When should iPCF-MC be used?
iPCF was developed to achieve short handover times when roaming between cells. The
iPCF-MC technique allows short handover times even for freely mobile clients and when a
lot of cells are involved or a large number of channels is being used.
Note
iPCF and iPCF-MC are not compatible with each other and cannot be used at the same
time on a device.
With 11n devices, remember that the assignment of the WLAN interfaces is fixed for
iPCF-MC.
WLAN1: Data interface
WLAN2: Management interface

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W722-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W722-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W722-1
CategoryControl Unit
LanguageEnglish

Related product manuals