Upkeep and maintenance
6.2 Restoring the default parameter settings
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
236 Configuration Manual, 11/2014, C79000-G8976-C350-03
6.2
Restoring the default parameter settings
Procedure
Follow the steps below to reset the device parameters to the factory settings:
Note
When you
reset the device parameters, all previously changed settings are lost!
1. Turn off the power to the device.
2. Now press the Reset button and reconnect the power to the device while holding down
the button.
3. Hold down the button until the red fault LED (F) stops flashing after approximately 10
seconds and is permanently lit.
4. Now release the button and wait until the fault LED (F) goes off again.
5. The device then starts automatically with the default parameters.