Configuring with Web Based Management
5.7 "Layer 2" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
209
Edge Type
Specify the type of the edge port. You have the following options:
"-"
Edge port is disabled. The port is treated as a "no EdgePort".
Admin
Select this option when there is always an end device on this port. Otherwise a
reconfiguration of the network will be triggered each time a connection is changed.
Auto
Select this option if you want a connected end device to be detected automatically at
this port. When the connection is established the first time, the port is treated as a "no
Edge Port".
Admin/Auto
Select these options if you operate a combination of both on this port. When the
connection is established the first time, the port is treated as an Edge Port.
Edge
Shows the status of the port.
Enabled
An end device is connected to this port.
Disabled
There is a spanning tree or rapid spanning tree device at this port.
With an end device, a switch can change over the port faster without taking into account
spanning tree frames. If a spanning tree frame is received despite this setting, the port
automatically changes to the "Disabled" setting for switches.
P.t.P. Type
Select the required option from the drop-down list. The selection depends on the port that
is set.
P.t.P.
Even with half duplex, a point-to-point link is assumed.
Shared Media
Even with a full duplex connection, a point-to-point link is not assumed.
Note
Point
-to-point link means a direct connection between two devices. A shared media
connection is, for example, a connection to a hub.
"-"
Point to point is calculated automatically. If the port is set to half duplex, a point-to-
point link is not assumed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W722-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W722-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W722-1
CategoryControl Unit
LanguageEnglish

Related product manuals