Configuring with Web Based Management
5.10 "iFeatures" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
234 Configuration Manual, 11/2014, C79000-G8976-C350-03
Description
The page contains the following boxes:
"Enable iPCF-MC" check box
Enable or disable the iPCF-MC mode of the device.
For PNIO communication, we recommend enabling the iPCF-MC mode. By enabling
iPCF-MC, the data rates provided by the access point are adapted.
We strongly recommend that you retain the default setting for the data rates (802.11 a/b/g
= 6, 9 and 12 Mbps and 802.11n = MCS 2).
"Management Scan Period" drop-down list
This parameter specifies the time between two management channel scans (specified in
iPCF cycles). If, for example, you select two, the client runs a management channel scan
only in every second iPCF cycle.
A lower value for the scan interval provides the basis for fast roaming, however this
means that no high data throughput can be achieved. A higher value should be selected
for a high data throughput.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W760 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W760 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W760 Series
CategoryControl Unit
LanguageEnglish

Related product manuals