3.3 PCS 7 redundancy concept
3.3.1 Advantages of the PCS 7 redundancy concept
Phases of a system lifecycle
High availability process control systems can be realized with SIMATIC PCS 7 at minimal cost
in all phases of a system lifecycle:
Configuration
Commissioning/operation
Servicing
Expansion
Advantages
PCS 7 offers the following essential advantages:
It provides you with system-wide scalable solutions based on the PCS 7 modular design.
Advantage: The availability can be matched to your requirements. Your process control
system can be upgraded with the SIMATIC PCS 7 components that are actually needed.
Hardware upgrades for high availability do not depend on the software configuration.
Advantage: If the user program has been configured with PCS 7, it does not have to be
adapted following a hardware upgrade. You only need to download the new hardware
configuration into the CPU.
High availability automation system S7-400H with CPU (types: see documentation
Process
Control System PCS 7; Released Modules
), whose module racks can be set up in separate
locations.
Advantage: Protection for the spatially separated CPUs resulting in increased availability
in case of fire or explosion, for example.
The use of redundant components in the process control system means isolated errors are
tolerated.
Advantage: The entire system does not fail when a single component in the process control
system fails. The redundant component takes over its tasks therefore allowing the process
to continue.
Every failure of a redundant component is indicated on the OS clients in the form of a
process control message.
Advantage: You immediately receive crucial information about the status of your redundant
component. Specific components that have failed can be quickly replaced to restore the
redundancy.
Software updates on redundant OS servers can be performed without loss of process
operability or loss of data.
Basics of high availability
3.3 PCS 7 redundancy concept
High Availability Process Control Systems (V9.0)
Function Manual, 05/2017, A5E39221836-AA 19

Table of Contents

Other manuals for Siemens SIMATIC PCS 7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC PCS 7 and is the answer not in the manual?

Siemens SIMATIC PCS 7 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC PCS 7
CategoryControl Systems
LanguageEnglish

Related product manuals