SIMATIC
PCS 7 Process Control System
ET 200PA SMART
Operating Instructions
06/2019
A5E34192013-AB
Preface
Product overview
1
Assignment planning
2
Installation
3
Connecting
4
Commissioning
5
Maintenance and service
6
Functions
7
Interrupt, error and system
messages
8
Interface module IM 650
9
ET 200PA SMART I/O
modules
10

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200PA SMART and is the answer not in the manual?

Siemens SIMATIC ET 200PA SMART Specifications

General IconGeneral
Product type designationET 200PA SMART
Bus SystemPROFIBUS PA
Supply voltage24 V DC
Input Voltage24 V DC
Protection ClassIP20
SeriesSIMATIC
SubseriesSMART
Communication InterfacePROFIBUS PA
Relative Humidity5% to 95% (non-condensing)
Connection MethodScrew-type terminal
DimensionsVaries depending on specific module type within the ET 200PA SMART series. Consult specific module documentation for exact dimensions.

Summary

Preface

Purpose of the operating instructions

Explains the scope and goal of the operating instructions for the ET 200PA SMART system.

Basic knowledge required

Outlines the prerequisite general experience needed to understand the manual.

Range of validity of these operating instructions

Specifies the product versions and modules covered by these operating instructions.

Position in the Information Landscape

Describes the ET 200PA SMART manual's place within the overall Siemens documentation.

Approvals, standards and certificates

Refers to section "Standards and approvals" for relevant certifications.

Guide

Information on access aids like table of contents and index for quick information retrieval.

SIMATIC Technical Support

Instructions on how to request technical support for Industry Automation products.

Service & Support on the Internet

Details on accessing online documentation, newsletters, and forums for product support.

Additional support

Information on finding personal Siemens representatives for further assistance.

Security information

Guidance on implementing industrial security concepts and product update recommendations.

Product overview

What Are Distributed I/O Devices

Explanation of distributed I/O devices and their application in automation systems.

What is PROFIBUS DP?

Definition and physical characteristics of the PROFIBUS DP bus system.

ET 200PA SMART Distributed I/O device

Definition and technical setup of the ET 200PA SMART Distributed I/O device.

Configuration of an ET 200PA SMART

Overview of components and their functions for configuring the ET 200PA SMART system.

Components

Detailed listing of essential components for ET 200PA SMART configuration and commissioning.

Assignment planning

2.1 Configuration variants

Explains limit conditions and module compatibility for ET 200PA SMART configurations.

2.2 Configuring the mechanical structure

Details on mounting dimensions, clearances, and rail lengths for ET 200PA SMART.

2.2.3 Arrangement of the modules for the function "Change During Operation" and / or "Redundancy"

Rules and guidelines for arranging modules for dynamic replacement and redundant operation.

2.3 Configuring the electrical structure

General rules and regulations for safe electrical integration of the ET 200PA SMART.

2.3.2 Operation of the ET 200PA SMART with process I/O on a grounded supply

Information on configuring ET 200PA SMART with grounded supply (TN-S system).

2.3.3 Configuration of the ET 200PA SMART with ungrounded reference potential

Details on configuring ET 200PA SMART with ungrounded reference potential for specific applications.

2.3.4 Configuration of the ET 200PA SMART with isolated modules

Explanation of using electrically isolated modules in the ET 200PA SMART configuration.

Installation

3.1 Overview

Introduction to preparing and installing ET 200PA SMART components.

3.2 Installation

General steps and considerations for installing the ET 200PA SMART system.

3.2.1 Mounting Sequence

Step-by-step procedure for physically installing the ET 200PA SMART system components.

3.2.2 Installing the DIN rail

Instructions for preparing and mounting the DIN rail for active bus modules.

3.2.3 Installing active bus modules and modules

Procedure for installing active bus modules and I/O modules onto the mounting rail.

3.2.4 After installation

Steps to perform after physical installation, including slot numbering.

3.3 Setting the PROFIBUS address

Guide on how to set the unique PROFIBUS address for the IM 650 interface module.

Connecting

4.1 Overview

Introduction to electrical configuration and basic rules for connecting the ET 200PA SMART.

4.2 Connecting PROFIBUS DP

Instructions for connecting the PROFIBUS DP network using appropriate bus connectors.

4.2.1 Connecting the Bus Connector

Details on applicable FastConnect bus connectors for PROFIBUS DP.

4.3 Wiring the power supply and modules

Essential wiring rules and procedures for power supply and modules.

4.3.1 Wiring rules

General wiring guidelines for power supply and IM 650 connections.

4.3.2 Wiring the power supply and IM 650

Step-by-step guide for wiring the power supply module and IM 650 with a connecting comb.

4.3.3 Wiring front connectors of the signal modules

Detailed instructions for wiring the front connectors of signal modules.

4.3.4 Connecting shielded cables via a shield connecting element

Procedure for connecting shielded cables to ground using a shield connection element.

Commissioning

5.1 PROFIBUS DP

Overview of PROFIBUS DP commissioning steps.

5.1.1 Commissioning the DP slave

Requirements and steps for commissioning the ET 200PA SMART as a DP slave.

5.1.2 Startup of the IM 650

Explanation of the startup process for the IM 650 interface module, including redundant configurations.

Maintenance and service

6.1 Maintenance of ET 200PA SMART

Information on the maintenance scope and limitations for the ET 200PA SMART.

6.2 Replacing the power supply module

Procedures for removing and installing a new power supply module.

6.3 Replacing the IM 650

Steps for safely removing and replacing the IM 650 interface module.

6.4 Replacing I/O modules

Instructions for replacing I/O modules, including module replacement in runtime.

6.5 Replacing the bus module

Procedure for removing and replacing bus modules in a de-energized state.

6.6 Exchanging fuses in digital output modules

Details on replacing fuses in specific digital output modules.

6.7 Update of the IM 650

Guidance on when and how to update the IM 650 interface module firmware.

Functions

7.1 Connection of HART field devices

Example configuration for connecting HART field devices using the ET 200PA SMART as a HART master.

7.2 Expanded I/O input data

Information on supporting up to 32 bytes of I/O input data with specific analog modules.

7.3 Support of additional input data

Details on how the IM 650 supports HART primary and secondary variables.

7.4 Time stamping of the input signals with IM 650

Principles and rules for time stamping digital input signals with the IM 650.

7.4.2 Time stamp with 10 ms precision

Requirements for achieving 10 ms time stamping precision for digital input signals.

7.4.3 Highly precise time stamp with 1 ms precision

Configuration rules for high-precision time stamping with 1 ms accuracy.

7.4.4 Time synchronization for time stamping

Requirements and settings for time synchronization for accurate time stamping.

7.4.5 Time stamping in the redundant system

How time stamping functions in a redundant system with IM 650 modules.

7.5 Time synchronization on the ET 200PA SMART I/O bus

How the IM 650 supports time synchronization on the I/O bus.

7.6 Redundancy with IM 650

Use cases and requirements for operating IM 650 modules redundantly.

7.7 System modification during operation

Possibilities for making system changes during runtime in redundant and non-redundant configurations.

7.8 Identification and maintenance data (I&M data)

Information about I&M data stored in modules for system checking and troubleshooting.

Interrupt, error and system messages

8.1 Concept for Drivers and Diagnostic Blocks

Explanation of the driver and diagnostic block concept for high-performance I/O interfacing.

8.2 Diagnostics of the IM 650 by LED displays

Interpretation of IM 650 status and error messages indicated by LED displays.

8.3 S7 diagnostics

Overview of S7 diagnostics structure and data for the IM 650.

8.3.1 Structure of slave diagnosis

Details on the structure and length of slave diagnostic data for the IM 650.

8.3.2 Station statuses 1 to 3

Explanation of station status bits providing an overview of DP slave status.

8.3.3 Master PROFIBUS address

Information on where the master PROFIBUS address is stored in diagnostic data.

8.3.4 Manufacturer ID

Definition and location of the manufacturer ID code for DP slaves.

8.3.5 Evaluating the slave diagnosis

Procedure for systematically evaluating slave diagnostics data.

8.3.6 Identifier-related diagnosis

Explanation of identifier-related diagnostics indicating faulty modules.

8.3.7 Module status

How module status reflects configured modules and identifier-related diagnostics.

8.3.8 Channel-specific diagnostics

Information on channel errors of modules and detailing of identifier-related diagnostics.

8.3.9 H-status, only in redundant configurations

Information on H-status provided by IM 650 when used with CPU 410 in redundant configuration.

8.3.10 Interrupts

Information on interrupt types and causes triggering slave diagnostic information.

8.3.11 Evaluating interrupts of device-related diagnostics

How to evaluate diagnostic and plug/pull interrupts in the DP master.

Interface module IM 650

Technical specifications

Overview of parameters, technical specs, response times, and drawings for the IM 650.

9.1 Parameters of the IM 650

Details on assigning parameters for the IM 650 and ET 200PA SMART via HW Config.

9.2 Technical specifications of the IM 650

Comprehensive technical specifications for the IM 650 interface module.

9.3 Response time of the ET 200PA SMART

Explanation of response time and factors affecting it for the ET 200PA SMART.

9.4 Use of the ET 200PA SMART in hazardous area zone 2

Information on using the ET 200PA SMART in hazardous area zone 2 environments.

ET 200PA SMART I/O modules

10.1 Module overview

Listing of available I/O modules for the ET 200PA SMART system.

10.2 Digital input modules

Overview of properties for ET 200PA SMART digital input modules.

10.2.1 Digital input module DI 32 x DC 24 V

Properties and article numbers for the DI 32 x DC 24 V digital input module.

10.2.2 Digital input module DI 16 x DC24V

Properties and article numbers for the DI 16 x DC 24 V digital input module.

10.2.2.1 Parameters of the DI 16 x DC 24 V

Assignable parameters and their default settings for the DI 16 x DC 24 V module.

10.2.2.2 Diagnostics of the DI 16 x DC 24 V

Introduction to module and channel faults for the DI 16 x DC 24 V module.

10.3 Digital output modules

Overview of properties for ET 200PA SMART digital output modules.

10.3.1 Digital output module DO 32 x DC 24 V/ 0.5 A

Properties and article numbers for the DO 32 x DC 24 V/0.5 A digital output module.

10.3.2 Digital output module DO 16 x DC 24 V/0.5 A

Properties and article numbers for the DO 16 x DC 24 V/0.5 A digital output module.

10.3.2.1 Parameters of the DO 16 x DC 24 V/0.5 A

Assignable parameters and default settings for the DO 16 x DC 24 V/0.5 A module.

10.3.2.2 Diagnostics of the DO 16 x DC 24 V/0.5 A

Introduction to module and channel faults for the DO 16 x DC 24 V/0.5 A module.

10.3.3 How to protect digital modules from inductive overvoltage

Methods to protect digital modules from inductive overvoltage.

10.4 Analog input modules

Overview of properties for ET 200PA SMART analog input modules.

10.4.1 Analog input module AI 8 x 13-bit

Properties and article numbers for the AI 8 x 13-bit analog input module.

10.4.1.1 Measurement types and measuring ranges

Configuration of measurement type and range for AI 8 x 13-bit module.

10.4.1.2 Parameters of the AI 8 x 13 bits

Assignable parameters and default settings for the AI 8 x 13 bits module.

10.4.1.3 Supplemental information on AI 8 x 13-bit

Additional information regarding unused channels and PTC resistor usage.

10.4.2 Analog input module AI 8 x 16 Bit

Properties and article numbers for the AI 8 x 16 Bit analog input module.

10.4.2.1 Parameters of the AI 8 x 16 Bit

Assignable parameters and default settings for the AI 8 x 16 Bit module.

10.4.2.2 Diagnostics of the AI 8 x 16 Bit

Introduction to module and channel faults for the AI 8 x 16 Bit module.

10.4.3 Analog input module AI 16 x 16 Bit

Properties and article numbers for the AI 16 x 16 Bit analog input module.

10.4.3.1 Parameters of the AI 16 x 16 Bit

Assignable parameters and default settings for the AI 16 x 16 Bit module.

10.4.3.2 Diagnostics of the AI 16 x 16 Bit

Introduction to module and channel faults for the AI 16 x 16 Bit module.

10.4.4 Analog input module AI 8 x TC/4 x RTD

Properties and article numbers for the AI 8 x TC/4 x RTD analog input module.

10.4.4.1 Parameters of the AI 8 x TC/4 x RTD

Assignable parameters and default settings for the AI 8 x TC/4 x RTD module.

10.4.4.2 Diagnostics of the AI 8 x TC/4 x RTD

Introduction to module and channel faults for the AI 8 x TC/4 x RTD module.

10.5 Analog output modules

Overview of properties for ET 200PA SMART analog output modules.

10.5.1 Analog output module AO 8 x 12 Bit

Properties and article numbers for the AO 8 x 12 Bit analog output module.

10.5.1.1 Parameters of the AO 8 x 12 Bit

Assignable parameters and default settings for the AO 8 x 12 Bit module.

10.5.1.2 Diagnostics of the AO 8 x 12 Bit

Introduction to module and channel faults for the AO 8 x 12 Bit module.

10.6 Module diagnostic information

Information on accessing current diagnostic data stored in data records.

10.7 Dimensional drawings of the signal modules

Provides dimensional drawings for ET 200PA SMART I/O modules.

10.8 Standards and approvals

Information on compliance with relevant standards and test criteria.

10.9 Approvals for the analog input module 6ES7650-8AE60-xAA0

Safety information and field of application for a specific analog input module.

10.10 Contact

Contact information for repair service and manufacturer details.