EasyManuals Logo

Siemens Simatic series Manual

Siemens Simatic series
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
Hardware Information
7-6
SIMATIC Rack PC IL 40 SManual
A5E00200171-01
7.4.3 Watchdog (WD)
Function
The watchdog monitors the execution of a program. The purpose of the WD is to
notify the user of a program crash through various reactions.
You will find more information on the CD supplied “Rack PC IL 40 S
Documentation and Drivers” in “wp_systemguard_en.pdf”.
7.4.4 Fan Monitoring
The operation of the front fan, the process fanand the power supply is monitored.
If a fan fails, the status LED on the front side is activated.
You will find more information on the CD supplied “Rack PC IL 40 S
Documentation and Drivers” in “wp_systemguard_en.pdf”.
7.5 Ports
The ports and their assignment on the motherboard are described in the
D1527.pdf manual on the CD supplied “Rack PC IL 40 S Documentation and
Drivers”.
7.6 Power Supply
Output Voltages
Voltage Max. Current Voltage Stability
+ 12 V 18 A " 5 %
– 12 V 1 A " 10 %
+ 5 V 20 A * +5 % / – 4 %
+ 3.3 V 18 A * + 5 % / – 4 %
+ 5 V aux 2 A + 5 % / – 3 %
* The total power consumption of the +5V and +3.3V voltages may not exceed 135 W.

Table of Contents

Other manuals for Siemens Simatic series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic series and is the answer not in the manual?

Siemens Simatic series Specifications

General IconGeneral
ProcessorIntel Core i3, Core i5, Core i7
Operating SystemWindows 10 IoT Enterprise, Linux
StorageSSD, HDD
InterfacesEthernet, USB, RS-232/485
PortsEthernet, USB, Serial
MountingDIN rail, wall
Protection ClassIP65
GraphicsIntegrated Intel HD Graphics
Expansion SlotsPCIe
Power Supply24V DC or 100-240V AC
Operating Temperature0°C to 50°C (depending on model)