Check the seals and sealing surfaces. Rectify the cause of the leak.
Check the insulators, connectors and cable connections in the terminal box.
Replace the damaged components if necessary.
WARNING
Short-circuit hazard
Short circuits, for example, can occur as a result of damaged components. This can result in
death, serious injury or material damage.
Replace damaged components.
Checking after subjection to heavy current
If the terminal box or the motor has been subjected to extremely heavy current, inspect the
electrical components.
9.1.12 Touch up any damaged paintwork
If the paint is damaged, it must be repaired in order to protect the unit against corrosion.
Note
Paint system
Contact the Service Center (Page 137) before you repair any paint damage. They will provide
you with more information about the correct paint system and methods of repairing paint
damage.
9.2 Repair
When carrying out any work on the machine, observe the general safety instructions
(Page 15) and the specifications contained in EN 50110‑1 regarding safe operation of electrical
equipment.
Note
If the motor has to be transported, please observe the information and instructions in the
"Transport" (Page 27) section.
Maintenance
9.2 Repair
SIMOTICS DC 1GG6
94 Operating Instructions 02/2016

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS DC 1GG6 and is the answer not in the manual?

Siemens SIMOTICS DC 1GG6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS DC 1GG6
CategoryEngine
LanguageEnglish

Related product manuals