Reworking the slots
If the commutator is skimmed, the slots should also be remachined, e.g. with a special saw.
The following diagrams give the recommended slot dimensions.
Image 9-2 Reworking the slots
Depending on the method used to machine the slots, it is useful to machine an undercut
as shown in the diagram below (detail X) when the commutator is skimmed. This undercut
must not be deeper than 1 mm for the smallest permissible commutator diameter.
Image 9-3 Final work on the commutator after skimming.
Final measures
After the commutator has been reworked, adjust the brush rocker and the brush holder
(Page 91).
9.1.11 Maintaining terminal boxes
Requirement
The machine is de-energized.
Checking for tightness
Terminal boxes must be regularly checked for tightness, undamaged insulation, and tight
terminal connections.
If dust or humidity have infiltrated the terminal box, this should be cleaned and dried
(particularly the insulators).
Maintenance
9.1 Inspection and maintenance
SIMOTICS DC 1GG6
Operating Instructions 02/2016 93

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS DC 1GG6 and is the answer not in the manual?

Siemens SIMOTICS DC 1GG6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS DC 1GG6
CategoryEngine
LanguageEnglish

Related product manuals