32910 DYN_MATCH_TIME
Time constant of dynamic adaption (control parameter set
no): 0...5
NEW_CONF
0 0.0 plus DOUBLE 2/7
32920 AC_FILTER_TIME
s Smoothing factor time constant for adaptive control POWER ON
_always 0.0 0.0 plus DOUBLE 2/7
33050 LUBRICATION_DIST
mm,
deg.
Traversing distance for lubrication from PLC NEW CONF
_always 100000000 0.0 plus DOUBLE 2/7
34000 REFP_CAM_IS_ACTIVE
Axis with reference point cam RESET
_always 1 *** ***
BOOLEAN
2/7
34010 REFP_CAM_DIR_IS_MINUS
Approach reference point in minus direction RESET
_always 0 *** ***
BOOLEAN
2/7
34020 REFP_VELO_SEARCH_CAM
mm/min,
rev/min
Reference point approach velocity RESET
_always 5000.0 0.0 plus DOUBLE 2/7
34030 REFP_MAX_CAM_DIST
mm,
deg.
Maximum distance to reference cam RESET
_always 10000.0 0.0 plus DOUBLE 2/7
34040 REFP_VELO_SEARCH_MARKER
mm/min,
rev/min
Creep speed (encoder no.) RESET
_always 300.0 0.0 plus DOUBLE 2/7
34050 REFP_SEARCH_MARKER_REVERSE
Direction reversal to reference cams (encoder no.) RESET
_always 0 *** *** BOOLEA 2/7
34060 REFP_MAX_MARKER_DIST
mm,
deg.
Maximum distance to reference mark. Max. distance to 2
reference marks
for distance–coded measuring systems.
RESET
_always 20.0 0.0 plus DOUBLE 2/7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802C base line and is the answer not in the manual?

Siemens SINUMERIK 802C base line Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802C base line
CategoryController
LanguageEnglish

Related product manuals