Description: Event-driven program calls (Prog-Events) can be set regarding their response on the
OPI.
The progStatus and chanStatus variables remain unaffected despite Prog-Event
processing being active
and retain the old value. This provides a means of concealing
Prog-Event processing from the HMI.
Bit 0 = 1 :
Reserved bit, ineffective
Bit 1 = 1 :
Prog-Event after end-of-part-program does not change progStatus and chanStatus
Bit 2 = 1 :
Prog-Event after OP reset does not change progStatus and chanStatus
Bit 3 = 1 :
Prog-Event after ramp-up does not change progStatus and chanStatus
Bit 4 = 1 :
Reserved
Bit 5 = 1 :
Safety-Prog-Event during ramp-up does not change progStatus and chanStatus
Corresponds to:
MD20105 $MC_PROG_EVENT_IGN_REFP_LOCK
MD20106 $MC_PROG_EVENT_IGN_SINGLEBLOCK
MD20107 $MC_PROG_EVENT_IGN_INHIBIT
MD20108 $MC_PROG_EVENT_MASK
MD20193 $MC_PROG_EVENT_IGN_STOP
20193 PROG_EVENT_IGN_STOP EXP -
- Prog-Events ignore the stop key DWORD NEW CONF
-
- - 0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0...
0 0xF 2/2 M
Description: Event-controlled program calls (Prog-Events) can be influenced with regard to their
behavior after pressing of the stop key.
The Stop, StopAll and StopAtEnd key of the PLC is ignored, if required.
Bit 0 = 1 :
Prog-Event after part program start delays the stop until the part program starts,
i.e. the stop only becomes active in the part program, not before its start. If the
part program starts with a traversing block, it is possible that it starts briefly,
i.e. a short motion occurs, although Stop has already been pressed in the Start-Prog-
Event.
Bit 1 = 1 :
Prog-Event after part program end ignores the stop
Bit 2 = 1 :
Prog-Event after operator panel reset ignores the stop
Bit 3 = 1 :
Prog-Event after power up ignores the stop
Corresponds to:
MD20105 $MC_PROG_EVENT_IGN_REFP_LOCK
MD20106 $MC_PROG_EVENT_IGN_SINGLEBLOCK
MD20107 $MC_PROG_EVENT_IGN_INHIBIT
MD20108 $MC_PROG_EVENT_MASK
MD20192 $MC_PROG_EVENT_IGN_PROG_STATE
Machine data
3.3 Channel-specific machine data
Parameter Manual
136 Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals