This information is used, among other things, for evaluating HMI, PLC and standard
cycles.
Meaning:
MD = 0: Milling
MD = 1: Turning
MD = 2: Grinding
21: Cylindrical grinding
22: Surface grinding
MD = 3: Nibbling
MD = 4: ...
(Enter additional technologies as and when required.)
27850 PROG_NET_TIMER_MODE C09 -
- Impact of the program runtime net counter DWORD Reset
-
- - 0x01 0x00 0x03 1/1 M
Description: The program run time is measured using system variables and can be read out. It
provides a means of outputting the current progress of the processing of a part
program. This MD can be used to make the following settings on a channel-specific
basis:
Bit 0 = 0
$AC_ACT_PROG_NET_TIME is not deleted on a jump to the start of the program with
GOTOS
Bit 0 = 1
$AC_ACT_PROG_NET_TIME is deleted on a jump to the start of the program with GOTOS, the
value is saved in $AC_OLD_PROG_NET_TIMES, and the program counter
$AC_OLD_PROG_NET_TIME_COUNT is incremented.
Bit 1 = 0
$AC_ACT_PROG_NET_TIME ceases to be increased if override = 0 is set; in other
words, the program run time is measured without the time for which the override was
set to 0.
Bit 1 = 1
$AC_ACT_PROG_NET_TIME is increased if override = 0; in other words, the program
run time is measured with the time for which the override was set to 0.
Bits 2 to 31
Reserved
27860 PROCESSTIMER_MODE C09 K1
- Activation and impact of program runtime measurement DWORD Reset
-
808d-me42 - 0x177 0 0x7FF 1/1 M
808d-me62 - 0x177 0 0x7FF 1/1 M
808d-te42 - 0x177 0 0x7FF 1/1 M
808d-te62 - 0x177 0 0x7FF 1/1 M
808d-mte40 - 0x00, 0x00, 0x00,
0x00, 0x00, 0x00,
0x00, 0x00...
0 0x7FF 1/1 M
808d-mte60 - 0x00, 0x00, 0x00,
0x00, 0x00, 0x00,
0x00, 0x00...
0 0x7FF 1/1 M
Machine data
3.3 Channel-specific machine data
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 193