Value = 0:
If 0 has been entered in the setting data, the active revolutional feedrate in JOG mode
is MD32050 $MA_JOG_REV_VELO "revolutional feedrate with JOG".
Each axis can be given its own revolutional feedrate with this MD (axial MD).
SD irrelevant for ......
For axes if SD41100 $SN_JOG_REV_IS_ACTIVE = 0
Application example(s)
The operator can define a JOG velocity for a particular application.
Related to ....
Axial SD41100 $SN_JOG_REV_IS_ACTIVE (revolutional feedrate for JOG active)
Axial MD32050 $MA_JOG_REV_VELO (revolutional feedrate with JOG)
Axial MD32000 $MA_MAX_AX_VELO (maximum axis velocity)
41130 JOG_ROT_AX_SET_VELO - H1
rev/min Axis velocity for rotary axes in JOG mode DOUBLE Immediately
-
- - 0.0 0.0 - 7/7 U
Description: Value not equal to 0:
The velocity entered applies to rotary axes in JOG mode (to continuous jogging,
incremental jogging, jogging with handwheel). The value entered is common to all
rotary axes, and must not exceed the maximum permissible axis velocity (MD32000
$MA_MAX_AX_VELO).
With DRF, the velocity set with SD41130 $SN_JOG_ROT_AX_SET_VELO must be reduced by
MD32090 $MA_HANDWH_VELO_OVERLAY_FACTOR.
Value equal to 0:
If the value 0 is entered in the setting data, the velocity applied to rotary axes in
JOG mode is the axial MD32020 $MA_JOG_VELO (jog axis velocity). In this way, it is
possible to define a separate JOG velocity for each axis.
Application example(s)
The operator can define a JOG velocity for a particular application.
Related to ....
MD32020 $MA_JOG_VELO (JOG axis velocity)
MD32000 $MA_MAX_AX_VELO (maximum axis velocity)
MD32090 $MA_HANDWH_VELO_OVERLAY_FACTOR (ratio JOG velocity to handwheel velocity (DRF)
41200 JOG_SPIND_SET_VELO - H1
rev/min Speed for spindle JOG mode DOUBLE Immediately
-
- - 0.0 0.0 - 7/7 U
Description: Value not equal to 0:
The speed entered applies to spindles in JOG mode if they are traversed manually by
the "Plus and minus traversing keys" or the handwheel. The speed is active for
continuous jogging
incremental jogging (INC1, ... INCvar)
handwheel traversing. The value entered is valid for all spindles, and must not
exceed the maximum permissible speed (MD32000 $MA_MAX_AX_VELO).
Value = 0:
If 0 has been entered in the setting data, MD32020 $MA_JOG_VELO (JOG axis velocity)
acts as the JOG velocity. Each axis can thus be given its own JOG velocity with this
MD (axial MD).
The maximum speeds of the active gear stage (MD35130 $MA_GEAR_STEP_MAX_VELO_LIMIT) are
taken into account when traversing the spindle with JOG.
NC setting data
Parameter Manual
304 Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals