808d-te42 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 0/0 S
808d-te62 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 0/0 S
808d-mte40 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 7/7 U
808d-mte60 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 7/7 U
Description: Fixed feedrate values for programming with F1 - F9. If the machine data
$MC_FEEDRATE_F1_F9_ON = TRUE is set with the programming of F1 - F9, the feedrate
values are read from SD42160 $SC_EXTERN_FIXED_FEEDRATE_F1_F9[0] - SD42160
$SC_EXTERN_FIXED_FEEDRATE_F1_F9[8], and activated as the machining feedrate.
The rapid traverse feedrate must be entered in SD42160
$SC_EXTERN_FIXED_FEEDRATE_F1_F9[0].
42162 EXTERN_DOUBLE_TURRET_DIST - FBFA
- Double turret head tool distance DOUBLE Immediately
-
- - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 7/7 U
Description: Distance between both tools of a double turret head.
42200 SINGLEBLOCK2_STOPRE - BA
- Activate SBL2 debug mode BOOLEAN Immediately
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 7/7 U
Description: Value = TRUE:
A preprocessing stop is made with every block if SBL2 (single block with stop after
every
block)
is
active. This suppresses the premachining of part program blocks. This
variant of the SBL2 is not true-to-contour.
This means that a different contour characteristic might be generated as a result of
the preprocessing stop than without single block or with SBL1.
Application: Debug mode for testing part programs.
42440 FRAME_OFFSET_INCR_PROG - K1, K2
- Work offsets in frames BOOLEAN Immediately
-
808d-me42 - FALSE 0 - 2/2 M
808d-me62 - FALSE 0 - 2/2 M
808d-te42 - FALSE 0 - 2/2 M
808d-te62 - FALSE 0 - 2/2 M
808d-mte40 - TRUE, TRUE, TRUE,
TRUE, TRUE, TRUE,
TRUE, TRUE...
0 - 7/7 U
808d-mte60 - TRUE, TRUE, TRUE,
TRUE, TRUE, TRUE,
TRUE, TRUE...
0 - 7/7 U
NC setting data
Parameter Manual