Machine data
2.3 Channel-specific machine data
Parameter Manual
100
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
Event-driven program calls (Prog-Events) can be set regarding their single-
block response.
Bit 0 = 1 :
Prog-Event after start-of-part-program causes block change without restart
Bit 1 = 1 :
Prog-Event after end-of-part-program causes block change without restart
Bit 2 = 1 :
Prog-Event after OP reset causes block change without restart
Bit 3 = 1 :
Prog-Event after ramp-up causes block change without restart
Bit 4 = 1 :
Prog-Event after 1st start after search causes block change without restart
Bit 5 = 1 :
Safety Prog-Event during ramp-up causes block change without restart
Corresponds to:
MD20105 $MC_PROG_EVENT_IGN_REFP_LOCK
MD20107 $MC_PROG_EVENT_IGN_INHIBIT
MD20108 $MC_PROG_EVENT_MASK
MD20192 $MC_PROG_EVENT_IGN_PROG_STATE
MD20193 $MC_PROG_EVENT_IGN_STOP
20106 PROG_EVENT_IGN_SINGLEBLOCK N01 K1,Z1
- Prog-Events ignore single block DWORD PowerOn
-
- - 0x1F 0 0x3F 2/2