Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
99
Machine data
2.3 Channel-specific machine data
Description: The behavior of event-driven program calls (prog-events) regarding non-refer-
enced axes can be set.
Bit 0 = 1 :
Prog-event ignores non-referenced axes after part program start
Bit 1 = 1 :
Prog-event after part program end ignores non-referenced axes
Bit 2 = 1 :
Prog-event after operator panel reset ignores non-referenced axes
Bit 3 = 1 :
Prog-event after power-up ignores non-referenced axes
Bit 4 = 1 :
Prog-event after 1st start after search ignores non-referenced axes
Bit 5 = 1 :
Reserved
Corresponds with:
MD20106 $MC_PROG_EVENT_IGN_SINGLEBLOCK
MD20107 $MC_PROG_EVENT_IGN_INHIBIT
MD20108 $MC_PROG_EVENT_MASK
MD20192 $MC_PROG_EVENT_IGN_PROG_STATE
MD20193 $MC_PROG_EVENT_IGN_STOP
The machine data MD20105 $MC_PROG_EVENT_IGN_REFP_LOCK and MD20115
$MC_IGNORE_REFP_LOCK_ASUP replace bit 1 from MD11602 $MN_ASUP_START_MASK.
If MD20700 $MC_REFP_NC_START_LOCK is equal to 0, the setting in MD20105
$MC_PROG_EVENT_IGN_REFP_LOCK is ignored, and non-referenced axes are always
ignored.
20105 PROG_EVENT_IGN_REFP_LOCK N01 K1,Z1
- Start Prog-Events despite non-referenced axes. DWORD PowerOn
-
- - 0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0...
0 0x3F 2/2
Siemens Controls