Machine data
2.4 Axis-specific machine data
Parameter Manual
214
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
The velocity entered applies to traversing in JOG mode when the axial fee-
drate override switch position is 100%.
This velocity is only used when general SD41110 $SN_JOG_SET_VELO = 0 for
linear axes, and linear feedrate is selected (SD41100 $SN_JOG_REV_IS_ACTIVE =
0) or SD41130 $SN_JOG_ROT_AX_SET_VELO = 0 for rotary axes.
If this is the case, the axis velocity is active for
• continuous jogging
• incremental jogging (INC1, ... INCvar)
• handwheel jogging
The value entered must not exceed the maximum permissible axis velocity
(MD32000 $MA_MAX_AX_VELO).
If DRF is active, the axis velocity for JOG must be reduced with MD32090
$MA_HANDWH_VELO_OVERLAY_FACTOR.
Spindles in JOG mode:
This machine data can also be used to define the JOG mode speed for specific
spindles (if SD41200 $SN_JOG_SPIND_SET_VELO = 0). However, the speed can be
modified with the spindle override switch.
Related to:
MD32000 $MA_MAX_AX_VELO
(maximum axis velocity)
MD32050 $MA_JOG_REV_VELO
(revolutional feedrate for JOG)
MD32090 $MA_HANDWH_VELO_OVERLAY_FACTOR
(ratio of JOG velocity to handwheel velocity (DRF))
SD41110 $SN_JOG_SET_VELO
(JOG velocity for G94)
SD41130 $SN_JOG_ROT_AX_SET_VELO
(JOG velocity for rotary axes)
NC/PLC interface signal DB3200 DBX4 (Feedrate override A-H)
32020 JOG_VELO A11, A04, - H1
mm/min, rev/
min
Jog axis velocity DOUBLE Reset
CTEQ
808d-me42 - 2000., 2000., 2000.,
36000.
(0./ 0.) (1.e300/ 1.e300) 2/2
808d-me62 - 2000., 2000., 2000.,
36000., 36000.
(0./ 0.) (1.e300/ 1.e300) 2/2
808d-te42 - 2000., 2000., 2000.,
36000.
(0./ 0.) (1.e300/ 1.e300) 2/2
808d-te62 - 2000., 2000., 2000.,
36000., 36000....
(0./ 0.) (1.e300/ 1.e300) 2/2