Machine data
2.4 Axis-specific machine data
Parameter Manual
258
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
Meaning of bit places:
Bit 0 = 0 and bit 1 = 0:
There is an invariable gear ratio between motor and load. The MD of the first
gear stage is active. Gear stage change is not possible with M40 to M45.
Bit 0 = 1:
Gear stage change at undefined change position. The gear can have up to 5
gear stages, which can be selected with M40, M41 to M45. To support the gear
stage change, the motor can carry out oscillating motions, which must be
enabled by the PLC program.
Bit 1 = 1:
Same meaning as bit 0 = 1, although the gear stage change is carried out in a
configured spindle position (SW 5.3 and higher). The change position is con-
figured in MD35012 $MA_GEAR_STEP_CHANGE_POSITION. The position is approached
in the current gear stage before the gear stage change. If this bit is set,
bit 0 is not taken into account!
Bit 2: Reserved
Bit 3 = 1:
The gear stage change dialog between NCK and PLC is simulated. The setpoint
gear stage is output to the PLC. A checkback signal from the PLC is not
awaited. The acknowledgment is generated internally in the NCK.
Bit 4: Reserved
Bit 5 = 1:
The second gear stage data set is used for tapping with G331/G332. The bit
must be set for the master spindle used for tapping. Bit 0 or bit 1 must be
set.
Related to:
MD35090 $MA_NUM_GEAR_STEPS (number of gear stages 1st data set, see bit 5)
MD35092 $MA_NUM_GEAR_STEPS2 (number of gear stages 2nd data set, see bit 5)
MD35110 $MA_GEAR_STEP_MAX_VELO (max. speed for autom. gear stage change)
MD35112 $MA_GEAR_STEP_MAX_VELO2 (max. speed for autom. gear stage change 2nd
data set, see bit 5)
MD35120 $MA_GEAR_STEP_MIN_VELO (min. speed for autom. gear stage change)
MD35122 $MA_GEAR_STEP_MIN_VELO2 (min. speed for autom. gear stage change 2nd
data set, see bit 5)
Description: Gear stage change position.
The value range must be within the configured modulo range.
Related to:
MD35010 $MA_GEAR_STEP_CHANGE_ENABLE, bit 1
MD30330 $MA_MODULO_RANGE
35010 GEAR_STEP_CHANGE_ENABLE A06, A11 P3 pl,P3 sl,S1
- Parameterize gear stage change DWORD Reset
CTEQ
- - 0x00 0 0x2B 2/2
35012 GEAR_STEP_CHANGE_POSITION A06, A11 S1
mm, degrees Gear stage change position DOUBLE NEW CONF
CTEQ
- 6 0.0, 0.0, 0.0, 0.0,
0.0, 0.0
0.0 - 2/2

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals