12.95
2.2 Ambient climatic and mechanical conditions
2-34
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) -- 11.02 Edition
2.2 Ambient climatic and mechanical conditions
2.2.1 Transport and storage conditions
IEC 68-2-1, IEC 68-2-2, IEC 68-2-3
The following specifications apply to components in transport packaging:
Table 2-7 Climatic conditions
Temperature range
See technical data of the relevant component
Relative air humidity U Annual average
U ≤75%
up to 30 days (24 hours) per
year
U ≤ 95%
Temperature change Within one hour < 10K
Atmospheric pressure The values specified apply to
a transportation altitude of up
to 3265m above mean sea
level
66kPa to 108kPa
Table 2-8 Mechanical conditions during transportation in original packaging
Vibratory load (according
to IEC 68-2-6)
Frequency range
5–9Hz
over 9–200Hz
Const. displacement
3.5mm
Ampl.ofacceleration
9.8 m/sec
2
Backup batteries must be transported in original packaging only. No special
approval is needed for transporting backup batteries. The lithium content is
approximately 300mg.
Note: The backup battery is classified in dangerous materials class 9 in
accordance with the relevant air-freight transportation regulations.
Applicable standards: DIN EN 60086(-4)
!
Warning
Improper handling of backup batteries involves the risk of ignition, explosion
and burning.
Relevant
standards
Components in
original packaging
Transportation of
backup batteries