04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–94
SINUMERIK 840C / SIMODRIVE 611–D (DA)
100008 ... (Alarm text is variable) OK softkey
–
Special error text
Explained by context of operation
–
100009 The area ..... is terminated OK softkey
–
–
–
–
100202 Error in file structure <%1>
Data management during job list processing
Processing job lists interrupted
Error in job list (workpiece does not exist, file opening/closing error)
Correct job list
Alarm from SW 6.3
100203 Timeout when executing an application in the job list
Data management while executing the CALL command in the job list.
The called application checks back within the WAIT time. Execution of the job list is aborted.
In the job list you have implemented a CALL instruction to initiate an MMC application. The WAIT parameter forms
a part of this CALL instruction. If the application does not check back properly within the projected time frame (file
sin840c.ini, Section Datenman, Entry Timeout), the forenamed alarm is issued.
Check the CALL instruction in the job list to verify that the path and application name are correct. Ascertain
whether the application is available on the MMC disk.
Alarm from SW 6.3
100204 File <%1> not transferred
Data management while executing the LOAD command in the job list or if file transfer is initiated in an application
with I–Code 421.
File is not transferred.
This error occurs in case of incorrect syntax when several part programs are being transferred.
Example: Comma omitted in MPF[1,999], i.e. entered as MPF[1999]
Correct the syntax
Alarm from SW 6.3
100205 Copying active <%1>
Data management on inch/metric changeover
None
When the inch/metric changeover is initiated, a message is issued to indicate that the relevant machine data are
being loaded.
Not applicable
Alarm from SW 6.3
100206 Workpiece <%1> does not exist
In the data management with ”Reload workpiece upon Power On”
Workpiece cannot be loaded into the NC.
This message is output if the workpiece to be loaded is not found (e.g. workpiece has been deleted on the MMC
disk or incorrect network connection).
Copy workpiece back to the MMC disk or establish network connection.
Alarm from SW 6.4
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description
01/9909/01