04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–157
SINUMERIK 840C / SIMODRIVE 611–D (DA)
160087 Max. acceleration too small OK softkey
Fine quantization too small
Coarse quantization too small
Number of learning runs too small
S Reparameterization of the maximum acceleration (function parameter of the neural quadrant error compensa-
tion)
S Reparameterization of the fine quantization (function parameter of the neural quadrant error compensation)
S Reparameterization of the coarse quantization (function parameter of the neural quadrant error compensation)
S Reparameterization of the number of learning runs (function parameter of the neural quadrant error compensa-
tion)
S Start-up function aborts
S Input of maximum acceleration zero is not allowed.
S Fine quantization must be greater than or equal to 4 and less than or equal to 32.
S Coarse quantization must be greater than 1.
S A number of learning runs less than 5 or greater than 40 is not allowed.
S Enter a larger value in the function parameter max. acceleration.
S Enter a valid value in the fine quantization.
S Enter a valid value in the coarse quantization.
S Enter a valid value.
160088 Axis/spindle name ... invalid OK softkey
DAC function parameterization
The function cannot be started
The stated axis/spindle does not exist
Correct input
160089 Axis/spindle number ... invalid OK softkey
DAC function parameterization
The function cannot be started
The stated axis/spindle does not exist
Correct input
160090 Hard disk full, create file ... OK softkey
Startup application file services
The data set in question is not stored
Note enough memory on hard disk
Remove file not required
160091 Data block of ... file invalid OK softkey
Startup application file services (read only)
No data is read
The contents of the selected file are not consistent
None
160092 File ... not loaded completely OK softkey
Startup application file services (read only)
The read data set is not complete
Contents of file were not transferred completely
Repeat procedure
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
1 Alarms