SINUMERIK 840C / SIMODRIVE 611–D (DA)
160120 Wrong Trace number (domain) ... OK softkey
Start-up application when reading out the TRACE buffer
Trace buffer could not be displayed
–
–
Applies as from SW 4
160121 Trace header not initialized (domain) ... OK softkey
Start-up application when reading out the TRACE buffer
Trace buffer could not be displayed
–
–
Applies as from SW 4
160122 Trace active, no data (domain) ... OK softkey
Start-up application when reading out the TRACE buffer while Trace function is running
Trace buffer could not be displayed
–
–
Applies as from SW 4
160123 Illegal trigger threshold ... OK softkey
Start-up application at start of SERVO TRACE function
SERVO trace is not started
–
–
Applies as from SW 4
160124 Option is not available OK softkey
Start-up application on selecting the circle form test function
Circle form test cannot be selected
–
Set circle form test option
Applies as from SW 4
160125 Trace buffer already assigned OK softkey
Start-up application on starting a measurement function
Measurement function is not started.
Trace buffer is already assigned by Servo Trace
Stop Servo Trace and restart measurement function
Applies as from SW 4
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note