Parameter Meaning
Use
Display
The protection area element is shown in the graphic view.
The element is only visible if the "Display model" softkey is active.
The element is not monitored for collision.
Monitoring
The protection area element is used for the collision avoidance.
The element is only visible if the "Monit. model" softkey is active.
Display and monitoring
The protection area element is used for display in the graphic view
and for collision avoidance.
The element is visible in both display versions.
Length (X) Length of the cube in the X direction.
Width (Y) Width of the cube in the Y direction.
Height (Z) Height of the cube in the
Z direction.
Offset (X) X component of the direction vector.
Offset (Y) Y component of the direction vector.
Offset (Z) Z component of the direction vector.
Rotary axis (X) X component of the rotation vector.
Rotary axis (Y) Y component of the rotation vector.
Rotary axis (Z) Z component of the rotation vector.
Angle of rotation The value by which the system rotates around the rotation vector.
See also