EasyManua.ls Logo

Siemens SINUMERIK 840DE SL - Page 435

Siemens SINUMERIK 840DE SL
1734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC1 drive alarm message
Displays (yes/no) whether messages of status class 1 are active. Status class 1 messages
are alarms with the following properties:
They lead to internal responses (e.g. regenerative braking, immediate pulse suppression)
They are modal.
This is a group message. For details on the actually pending drive alarms, please refer to the
"Drive System Diagnostics" window, see Section "Displaying drive states (Page 450)."
DC-link voltage, smoothed
The display of the smoothed actual value of the DC-link voltage of the selected drive
corresponds to the drive parameter:
r0026 "DC-link voltage smoothed".
Unit: Volts
Speed setpoint, smoothed
The display of the smoothed speed setpoint - measured according to the setpoint limitation for
the P component of the speed controller - corresponds to the drive parameter:
r1438 "Speed controller speed setpoint".
Unit: rpm
Actual speed value
The display of the smoothed actual value of the motor speed corresponds to the drive
parameter:
r0021 "Actual speed value smoothed".
Unit: rpm
Actual current value, smoothed
The display of the smoothed actual current value corresponds to the drive parameter:
r0078[1] "Actual current value, torque-generating".
Unit: A
Motor temperature
The display of the current temperature in the motor corresponds to the drive parameter:
r0035 "Motor temperature"
Unit: °C
Service and diagnostics
18.2 Displaying the Service overview
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 421