Technical speci󹪝cations
7
7.1 Handheld Terminal HT 10
Handheld Terminal HT 10
Safety
Safety class III according to UL 61010-2-201
Degree of protection accord‐
ing to DIN EN 60529
IP65
Approvals CE/cULus/EAC/KC/RCM
Electrical data
Input voltage 24 V DC (20.4 V ... 28.8 V)
Input current 0.98 A
Current carrying capacity Enabling button: 10 ... 250 mA / 1-channel, 3-stage
Emergency Stop button: 10 - 1000 mA / 2-channel
Max. current carrying capaci‐
ty
USB interface: 900 mA
Mechanical data
Dimensions (W x H x D) 327 mm x 102 mm x 232 mm (enclosure dimensions only)
Weight 1.5 kg
Fall height, max. 1.20 m
Display
Size 10.1" TFT
Resolution 1280 x 800 pixels
Service life At ambient temperatures of > 40º C and long periods of non-use, it is
advisable to activate the screen saver function.
Emergency Stop button
Rated voltage 24 V DC
Current rating, max. 1 A
Current rating, min. 18 mA
Switching capacity DC 13 according to EN 60947-5-1
Conditional rated short-circuit current 10 A gL/gG according to EN 60947-5-1
B
10d
(if a connection box is not used) 250000
When using the connection box advanced:
PFH
d
1.01 * 10
-7
Service life 20 years
Forced dormant error detection interval (mechanical actua‐
tion to the test the emergency stop)
1 year
Handheld Terminal HT 10
Equipment Manual, 09/2020, A5E47430965B AA 79

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK HT 10 and is the answer not in the manual?

Siemens SINUMERIK HT 10 Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK HT 10
CategoryTouch terminals
LanguageEnglish

Related product manuals