7.4.4 EMC limiting values in South Korea
EMC limit values in South Korea
The EMC limit values to be complied with for South Korea correspond to the limit values of the
EMC product standard for variable-speed electric drives EN 61800-3, Category C2, or limit value
class A, Group 1 according to EN 55011. By applying suitable supplementary measures, the limit
values according to Category C2 or according to limit value class A, Group 1, are maintained.
Further, additional measures may be required, for instance, using an additional radio
interference suppression lter (EMC lter).
The measures for EMC-compliant design of the system are described in detail in this manual
respectively in the Installation Guideline EMC.
Please note that the nal statement on compliance with the standard is given by the respective
label attached to the individual unit.
7.4.5 EMF assessments for 24 V components
The 24 V components, e.g. control systems (NCU, MCU, PPU), PCUs/IPCs, operator panels,
handheld terminals and machine control panels do not generate any appreciable
electromagnetic elds.
No minimum clearance has to be maintained for 24 V components.
7.5 Climatic and mechanical ambient conditions
7.5.1 Shipping and storage conditions
In respect of shipping and storage conditions, the components surpass the requirements of
EN 61800-2.
The following data applies under the following conditions:
• Long-term storage in the transport and product packaging:
At weather-protected locations that have continuous contact with outside air through
openings.
• Transport in the transport packaging:
– In unventilated containers under conditions not protected from weather eects.
– In the “cold" in accordance with outside air.
– Air transport in the air-conditioned cargo hold.
Technical specications
7.5 Climatic and mechanical ambient conditions
Handheld Terminal HT 10
86 Equipment Manual, 09/2020, A5E47430965B AA