Connection box standard and advanced with HT 10,
typical
approx. 600 mA
Fuse, internal Electronic
Current load PLC-accompanying signals Max. 100 mA
Note
Recovery time
After unplugging the connecting cable from the connection box wait for approximately one
second before reinserting it.
After power failures lasting less than one second the connecting cable has to be disconnected.
7.4 Supplementary electrical conditions
Ambient conditions Remarks
Overvoltage category OVC 2
EMC conducted / radiation Class C2 according to EN 61800-3
Note
The user must consider radio interference for the complete system. Particular attention should
be paid to cabling. Please contact your sales representative for assistance and support.
Note
Disturbance of radio communication services due to radio (frequency) interferences in
residential environments
In a residential environment, this product can cause high-frequency interference, which may
make interference suppression measures necessary.
This device is not designed for unrestricted operation in the rst environment (residential
environment), and may not be used in the rst environment without suitable interference
suppression measures.
• Have the installation and commissioning with appropriate radio interference suppression
measures performed by qualied personnel.
Technical specications
7.4 Supplementary electrical conditions
Handheld Terminal HT 10
82 Equipment Manual, 09/2020, A5E47430965B AA