Ambient conditions Application areas Remarks
Relative humidity (with‐
out condensation)
5% to 95% (60% when corrosive gases and/or dusts are present)
Condensation, icing,
drip, spray and splash
water
Not permitted
Max. installation alti‐
tude
Up to 4 000 m (13 123 ft) above sea level
Air pressure 620 ... 1060 hPa
Biological, chemical and mechanical inuences, pollutants
Biological environmental conditions Class 3B1 according to EN 60 721‑3‑3:
Mold, mold growth, slime, rodents, termite and other
animal vermin are not permissible.
Mechanically active environmental conditions Class 3S1 according to EN 60721‑3‑3:
Conductive dust not permitted.
Classication of the mechanical
environment
3M3 for components on the machine
3M1 / 3M2 for components in the control cabinet
Vibratory load Frequency range: 10 ... 150 Hz
Deection at 10 – 58 Hz: 0.075 mm
Acceleration at 58 ... 150 Hz: 1 g
Shock load with shock-sensitive components Acceleration: 5 g
Shock duration: 30 ms
Load: 3 x in each direction
Pollution degree 2 (for indoor use only)
Type of enclosure Type 1
Overvoltage category OVC 2
EMC conducted / radiation Class C2 according to EN 61800-3
1) At an ambient air temperature of 45 °C, exposed parts of the device may heat up to 65 °C.
Note
The user must consider radio interference for the complete system. Particular attention should
be paid to cabling. Please contact your sales representative for assistance and support.
Note
In a residential environment, this product can cause high-frequency interference, which may
make interference suppression measures necessary.
• Have the installation and commissioning with appropriate radio interference suppression
measures performed by qualied personnel.
Technical specications
7.5 Climatic and mechanical ambient conditions
Handheld Terminal HT 10
88 Equipment Manual, 09/2020, A5E47430965B AA