Universal outputs X515 / X516
The outputs are provided for the activation of LEDs in the keys.
High-side switches that switch 24 V to the lamps and limit the current during short circuits are
used as output drivers.
0
0



3
.7287
.7287
.7287

Figure 5-2 Schematic circuit diagram
Table 5-7 Technical data
Parameter Value
Voltage
1)
24 V (20.4 V ...
28.4 V)
Maximum load current per output 0.5 A
Max. load current per connector 1 A
Max. load current per output at 100% simultaneity of all 16 outputs 0.15 A
Electrical isolation None
1) Supplied directly via connector X10
5.1.6 USB upstream port X120
USB upstream port X120
The interface is designed as a "high powered interface" (5 V/500 mA). As a result, the USB hub
can only be connected to USB interfaces which possess their own power supply and whose
downstream ports are capable of supplying a 500 mA current. A standard USB 2.0 Hi-Speed
cable of max. 3 m in length (recommended: 1.5 m) is supported.
Connector designation: X120
Connector type: USB-B connector, 4-pin