A.9 Information List
SIPROTEC, 7SJ62/64, Manual
C53000-G1140-C207-2, Release date 01.2008
678
7560 67N-1 InRush picked up (67N-1
InRushPU)
50/51 Overcur. OUT * On
Off
* LED BO 60 85 2 Yes
7561 67-TOC InRush picked up (67-
TOC InRushPU)
50/51 Overcur. OUT * On
Off
* LED BO 60 86 2 Yes
7562 67N-TOC InRush picked up
(67N-TOCInRushPU)
50/51 Overcur. OUT * On
Off
* LED BO 60 87 2 Yes
7563 >BLOCK InRush (>BLOCK
InRush)
50/51 Overcur. SP * * * LED BI BO
7564 Ground InRush picked up (Gnd
InRush PU)
50/51 Overcur. OUT * On
Off
* LED BO 60 88 2 Yes
7565 Phase A InRush picked up (Ia
InRush PU)
50/51 Overcur. OUT * On
Off
* LED BO 60 89 2 Yes
7566 Phase B InRush picked up (Ib
InRush PU)
50/51 Overcur. OUT * On
Off
* LED BO 60 90 2 Yes
7567 Phase C InRush picked up (Ic
InRush PU)
50/51 Overcur. OUT * On
Off
* LED BO 60 91 2 Yes
10020 >BLOCK Load Jam Protection
(>BLOCK Jam Prot)
48/66 Motorprot SP On
Off
LED BI BO
10021 Load Jam Protection is
BLOCKED (JAM PROT.BLOCK.)
48/66 Motorprot OUT On
Off
LED BO
10022 Load Jam Protection is OFF
(JAM PROT.OFF)
48/66 Motorprot OUT On
Off
LED BO
10023 Load Jam Protection is ACTIVE
(JAM PROT.ACTIVE)
48/66 Motorprot OUT On
Off
LED BO
10024 Load Jam Protection alarm (Load
Jam alarm)
48/66 Motorprot OUT On
Off
* LED BO
10025 Load Jam Protection picked up
(Load Jam pickup)
48/66 Motorprot OUT On
Off
* LED BO
10026 Load Jam Protection TRIP (Load
Jam TRIP)
48/66 Motorprot OUT On
Off
* LED BO
10027 Startup Duration 1
(StartDuration1)
Mot.Statistics VI
10028 Startup Current 1
(StartupCurrent1)
Mot.Statistics VI
10029 Startup Voltage 1
(StartupVoltage1)
Mot.Statistics VI
10030 Total Number of Motor Starts
(Nr.of Mot.Start)
Mot.Statistics VI
10031 Total Motor Running Time (Motor
Run.Time)
Mot.Statistics VI
10032 Total Motor Stopped Time (Motor
Stop.Time)
Mot.Statistics VI
10033 Motor Percent Running Time
(Perc.Run.Time)
Mot.Statistics VI
10034 50-3 BLOCKED (50-3
BLOCKED)
50/51 Overcur. OUT On
Off
On
Off
* LED BO
10035 50N-3 BLOCKED (50N-3
BL
OCKED)
50/51 Overcur. OUT On
Off
On
Off
* LED BO
10037 Startup Duration 2
(StartDuration2)
Mot.Statistics VI
10038 Startup Current 2
(StartupCurrent2)
Mot.Statistics VI
10039 Startup Voltage 2
(StartupVoltage2)
Mot.Statistics VI
10040 Startup Duration 3
(StartDuration3)
Mot.Statistics VI
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation