EasyManua.ls Logo

Siemens SIRIUS 3RW5 - Ethernet Link Object

Siemens SIRIUS 3RW5
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.11 Ethernet Link Object
SIRIUS 3RW5 EtherNet/IP communication module
108 Manual, 05/2019, A5E45131885002A/RS-AA/001
A.11 Ethernet Link Object
The "Ethernet Link" object saves link-specific counters and status information for an
IEEE 802.3 communications interface.
The following information applies to the Ethernet Link Object of the
3RW5 EtherNet/IP communication module:
Class code: 0xF6
Class attributes: 1 ... 3
Number of instances: 1
The definition of the instance attributes corresponds to the CIP specification, Volume 2. All of
the instances defined there as "required" are supported.
General services
Service code
Available service
Service
Description
Class
Instance
0x01
Yes
Yes
Get_Attributes_All
Supplies the contents of all attributes.
0x0E
Yes
Yes
Get_Attributes_Single
Supplies the contents of one attribute.
0x10 No Yes Set_Attributes_Single Changes the contents of an attribute.
Class attributes
Attribute ID
Access
Class attribute
Data type
1
Get
Revision
UINT
2
Get
Max Instance
UINT
3
Get
Number of Instance
UINT