Appendix
A.9 Dataset Object
SIRIUS 3RW5 EtherNet/IP communication module
Manual, 05/2019, A5E45131885002A/RS-AA/001
103
A.9.5 HMI parameters
Read access (get, r) and write access (set, w) is possible to the HMI parameters.
The instance and the attribute ID of all HMI parameters is 25409 (0x6341).
Byte
Bit
Data
format
Parameters
Range of values
[encoding]
Increment
3RW5
HMI HF
1)
[D
2)
]
463 0 USINT Language
[0 ... 254]
- r/w
[0]
[0] English
[1] German
[2] French
[3] Spanish
[4] Italian
[5] Chinese
[6] Portuguese
465 0 UINT Display shutdown delay 1 60 min
[1 60]
1 min r/w
[5]
[0] Deactivated
467 0 BOOL Display time
[0 ... 1]
- r/w
[0]
[0] Disable
[1] Enable
469 0 BOOL Do Control After Logoff
[0 1]
- r/w
[0]
[0] Stop motor and give back control
[1] Continue with motor control
470 ... 476
-
-
Reserved
-
-
-
1)
Supported by 3RW5 HMI High Feature as from 3RW5 HMI High Feature V2.0
2)
Default encoding