Requirements
Data Backup of SINAMICS S120
SINAMICS S120 at Technology CPU Entry ID: 21767896
V1.0 Edition 10/28/05 31/58
Copyright © Siemens AG 2005 All rights reserved
SINAMICS S120 und Technologie-CPU V2.0-SP1__05-10-28_13-20_e.doc
Table 4-4 Recovery of the backed up drive data
No. Instruction Note
1.
In the SIMATIC Manager, select
SINAMICS_S120 and double-click
this component in the right
window.
This starts S7T Config for
SINAMICS S120.
2.
In the Project menu, establish the
online connection to SINAMICS
S120 by selecting the menu item
Connect to target system.
3.
Via the Download to target
device… context menu of
SINAMICS_S120, load all
parameters and BICO
interconnections to the configuration
computer.
To permanently store the data, it is required to subsequently copy the data
from RAM to ROM, i.e. to again store the data on the compact flash card.