Loading...
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification
Unrestricted
Page
127 of 154
Version
7
Status
Issued
Last Editor
manpreet.jeerh
Date
January 2020
Document Name
ST950 ICM Handbook
Document No.
667/HE/45950/000
Figure 56 - Fault Table on completion of restoration from Heart
Restoring from the Heart Using WIZ
It is only possible to restore the most recent Restore Point when using WIZ. To start
the operation, invoke WIZ from the handset command line and select the Heart
menu item from the top level WIZ menu.
The user is presented with a sub-menu containing the following two options.
1> Own Heart
2> Restore
Select option 2.
The controller reads the available restore points from the Heart and outputs the
following. NOTE : The restore point name shown below is representative of a typical
restore point.
Restore from:
ST950-LV32B
Y/N?
Selecting “N” will display the following.
Restore not
started.
Press any key
Pressing any key returns to the original sub-menu. If no key is pressed, the user is
automatically returned to the sub-menu after a few seconds.
Selecting “Y” will display the following.
Switch signals off
and press the PRG
button.