4.9.1 I/O Card Status LEDs
The I/O card has three tri-colour status LEDs as shown in
Figure 21, which are used to indicate various conditions, as follows:
Comms Active LED
(LP1)
Software Run LED
(LP2)
Watchdog LED
(LP3)
State
Yellow
Yellow
Off
Processor Reset
Yellow
Yellow
Red
Watchdog Failure
Off
Green Steady
Off
Performing Start Up
Red
Green Flash
Off
Awaiting Start
Green Toggle on
Receipt of Message*
Green Flash
Off
Communications
Active
Off
Green / Red
Alternating
Off
Invalid Address
(As above depending
on state)
Red Flash
Off
Major Fault Detected
* - May flash so fast that it looks like Green Steady.
Table 6 I/O Card LEDs
Conditions other than those identified above should not occur and can be treated as
faults.
4.9.2 I/O Card Rotary Address Switch
This screwdriver-adjustable switch is located on the I/O card(s) as shown in
Figure 21 and is set up for the card address (before the controller is powered up) in
accordance with the appropriate Works Specification. The valid address range is 1
through 15 (where A to F denote 10 to 15 respectively). Address 0 is the default
address switch position for spare cards.
The address range is shared with the Intelligent Detector Backplane
cards and must be unique.